click here to chat with us
RGN400-2

RGN400-2 DC Motor Control

Legacy

The RGN Series, with a robust set of features, is easy to use and at the same time, will satisfy demanding application requirements. The RGN will accept any AC input voltage between 90 and 240 VAC at 50 of 60 Hz. With the auto-ranging power supply, there are no switches to set or settings to change. These highly efficient, near unity form factor PWM regenerative drives will increase motor performance while reducing your energy costs. MOSFET power in PWM drives switch at 16 kHz (double edge modulation), to provide fast circuit response and the constant 1.05 form factor through the entire 100:1 speed range.


Potentiometer Kit 202-0003 is included with a purchase of the RGN400-2

Let's Talk About Your Project

$1,045.65

Contact the factory for volume pricing

Model
Number
Enclosure Maximum
Current
(ADC)
Input
Voltage
(VAC)
Output
Voltage
(VDC)
Power Range
SCR Rated (PWM Rated)
Field /
Shunt
Supply
Braking Reversing Isolation
HP kW
RGN400-2 Chassis 2 115 0 - 90 / 130 1/20 - 1/5 (1/4) .04 - .15 (.19) No Yes
(Regenerative)
Yes
(Regenerative)
No
230 0 - 90 / 130 1/20 - 1/5 (1/4) .04 - .15 (.19)
0 - 180 / 240 1/10 - 1/3 (1/2) .07 - .25 (.37)

 

Features

  • Auto Ranging Input: No input voltage switches to set
  • Accepts AC or DC Input: Can accept 80-340 VDC or 90-240 VAC input
  • Stopping Modes: Enable (N.C.) can be set for coast or brake. Can be used for rapid starting and stopping
  • Dumb Circuitry: Internal circuitry for the hookup of an external dump resistor
  • 4Q Reversing: Regenerative / 4-Quadrant drives have the ability to perform quick and contactorless braking and/or reversing-on-the-fly
  • Diagnostic LEDs: Motoring, Regen (torque or braking), Current Limit, Overvoltage Coast

Technical Data

  • 1.05 Form Factor
  • 1% Base Speed Regulation
  • 100:1 Speed Range

Trim Pots

  • Forward Acceleration
  • Inhibit Offset
  • Input Offset
  • IR Compensation
  • Maximum Forward Speed
  • Maximum Reverse Speed
  • Minimum Speed
  • Motoring Current Limit
  • Regen Current Limit
  • Reverse Acceleration
  • Tach Feedback

Product Downloads