Competitor Search
click here to chat with us
RGA440-3-CYC Cycling Controls

RGA440-3-CYC Cycling Control

RGA-CYC Series

The RGA-CYC Series is our RGA400 controls with an added logic board. These controls are dual voltage, fully-featured regen drives in a rugged enclosure. These high performance controls maintain motor speed with automatic motoring and braking torque, while allowing high-duty cycle reversing and braking, great for limit switch applications. The RGA-CYC have conveniently mounted operators. Included are a power on/off switch and separate forward and reverse speed potentiometers so independent speeds for each direction can be easily set. Controlling the motor is easy too, by pressing a button on the membrane panel for stop, run, reverse, or jog (jog speed is adjustable). The user can also wire in remote pushbuttons in conjunction with the on-board buttons. These controls can operate in several modes with either one or two limit switches, including continuous cycling, single cycle, dwell and more - including adjustable stop and dwell times!

Please login to view pricing.

Contact the factory for volume pricing

Model
Number
Enclosure Maximum
Current
(ADC)
Input
Voltage
(VAC)
Output
Voltage
(VDC)
Power Range Field / Shunt
Supply
Braking Reversing Isolation
HP kW
RGA440-3-CYC NEMA 4X 3 115 0 - 90 1/20 - 1/4 .04 - .19 50 / 100 Yes
(Regenerative)
Yes
(Regenerative)
No
230 0 - 90 1/20 - 1/4 .04 - .19 100 / 200
0 - 180 1/10 - 1/2 .07 - .37

Features

  • Cycling Mode: Designed to run in automatic cycle, single cycle, or jog mode with 1 or 2 limit switches
  • Membrane Switches: Front cover includes built-in membrane switches
  • Independent Forward and Reverse Speeds: Two potentiometers on front cover allow different speeds in the forward and reverse directions
  • NEMA 4X Enclosure: Water resistant and dust proof enclosure
  • Field Supply: Voltage output to energize the field winding of a shunt-wound motor
  • On-board Fusing: Drives include on-board fusing
  • 4Q Reversing: Regenerative / 4-Quadrant drives have the ability to perform quick and contractorless braking and/or reversing-on-the-fly
  • Tach Feedback: Accepts tachogenerator feedback for tighter speed regulation
  • Case LEDs: Forward, Reverse, Stop, Jog
  • Pre-Wired Switches: ON/OFF

Technical Data

  • 1.37 Form Factor
  • 1% Base Speed Regulation
  • 0.1% Base Speed Regulation with Tach Feedback
  • 60:1 Speed Range

Trim Pots

  • Maximum Speed
  • Minimum Speed
  • Forward Acceleration
  • Forward Deceleration
  • Forward Torque
  • Reverse Torque
  • IR Compensation
  • Tach Feedback
  • Deadband
  • Forward Jog
  • Reverse Jog
  • Dwell Time

Product Downloads

Quick Start Guide