Model Number |
Enclosure |
Maximum Current (ADC) |
Input Voltage (VAC) |
Output Voltage (VDC) |
Power Range |
Field / Shunt Supply |
Braking |
Reversing |
Isolation |
HP |
kW |
RGA410-10 |
NEMA 1 |
10* |
115 |
0 - 90 |
1/8 - 1 |
.09 - .75 |
No |
Yes (Regenerative) |
Yes (Regenerative) |
No |
230 |
0 - 90 |
1/8 - 1 |
.09 - .75 |
0 - 180 |
1/4 - 2 |
.19 - 1.5 |
* Heat sink kit 223-0174 must be used when the continuous output current is above 5 amps.
Features
- 4Q Reversing: Regenerative / 4-Quadrant drives have the ability to perform quick and contactorless braking and/or reversing-on-the-fly
- Field Supply Voltage output to energize the field winding of a shunt-wound motor
- Tach Feedback: Accepts tachogenerator feedback for tighter speed regulation
- On-board Fusing: Drives include on-board fusing
- Diagnostic LEDs: Power, Forward Current Limit, Reverse Current Limit, Forward Direction, Reverse Direction
- Case Lights: Power
|
Technical Data
- 1.37 Form Factor
- 1% Base Speed Regulation over 50:1 Speed Range
- 0.1% Base Speed Regulation over 60:1 Speed Range with Tach
|
Trim Pots
- Maximum Speed
- Minimum Speed
- Forward Acceleration
- Reverse Acceleration
- Forward Current Limit
- Reverse Current Limit
- IR Compensation
- Tach
|