Competitor Search Guided Search
click here to chat with us
MGC403-11

MGC403-11

MGC Series

$199.00
Model
Number
Enclosure Maximum
Current
(ADC)
Input
Voltage
(VAC)
Output
Voltage
(VDC)
Power Range Field / Shunt
VoltageĀ 
(VDC)
Braking Reversing Isolation
HP kW
MGC403-11 Chassis 11* 115 0 - 90 1/8 - 1 .09 - .75 50 / 100 Yes
(Regenerative)
Yes
(Regenerative)
0 Ā± 10 VDC
4-20 mA
230 0 - 90 1/8 - 1 .09 - .75 100 / 200
0 - 180 1/4 - 2 .19 - 1.5

* Heat sink kit 223-0159 must be used when the continuous output current is above 8 amps.

Features

  • ACE Footprint: Traditional ACE mounting pattern and footprint
  • Microprocessor Based: Allows custom programming for OEMs
  • Dual Analog Inputs: MGC models can accept 2 command signals, making wiring easier for applications requiring two potentiometers, a Run/Jog, or Auto/Manual setup. Also allows for individual control of speed and torque
  • 7 Modes of Operation:
    • Speed
    • Torque
    • Linear Torque
    • Independent Speed & Torque
    • Cycling with Limit Switches
    • Cycling with Feedback
    • Positioning
  • Field Supply: Voltage output to energize the field winding of a shunt-wound motor
  • 4Q Reversing: Regenerative / 4-Quadrant drives have the ability to perfrom quick and contactorless braking and/or reversing on-the-fly
  • Stopping Modes: Inhibit for braking to a stop. Enable for coasting to a stop. Can be used for rapid starting and stopping
  • Configurable Enable and Inhibit: Can be configured to be either normally open or normally closed
  • 3-Wire Start/Stop: Inhibit and Enable can be setup to mimic a 3-Wire Start/Stop
  • Quick Disconnect Terminal Allows for quicker wiring and setup
  • Diagnostic LEDs: Current Limit

Technical Data

  • 1.37 Form Factor
  • 1% Base Speed Regulation
  • 60:1 Speed Range

Trim Pots

MGC models have 9 adjustable user trim pots. The function of the trim pot is dependent on the mode of operation.
Trim Pots Speed & Torque Modes Cycling w/ Limits Mode Cycling w/ Feedback Mode Positioning Mode
MOP
Motor Overload Protection
FWCL
Forward Current Limit
RVCL
Reverse Current Limit
MAX
Maximum Speed
FACC
Forward Accel / Reverse Decel
Forward & Reverse Acceleration
RACC
Forward Decel / Reverse Accel   Forward & Reverse Deceleration
Reverse Dwell Time Error Gain 
OFS1 Signal 1 Offset / Minimum Speed Minimum Speed Retract Position
OFS2 Signal 2 Offset / Minimum Speed
Reverse Dwell Time Extend Position
IR/T IR Compensation / Tach Forward Dwell Time IR Compensation / Tach

Product Downloads