Model Number |
Enclosure |
Maximum Current (ADC) |
Input Voltage (VAC) |
Output Voltage (VDC) |
Power Range |
Field / Shunt Supply |
Braking |
Reversing |
Isolation |
HP |
kW |
LGM103-10 |
Chassis |
10* |
115 |
0 - 90 |
1/8 - 1 |
.09 - .75 |
50 / 100 |
No |
No |
0 - 10 VDC 4 - 20 mA |
* Heat sink kit 223-0159 must be used when the continuous output current is above 5 amps.
Features
- ACE Footprint: Traditional ACE mounting pattern and footprint
- Isolated Logic: Allows floating or grounded 0 - 10 VDC signal
- Field Supply: Voltage output to energize the field winding of a shunt-wound motor
- Stopping Modes: Inhibit (N.O. or N.C.) for coasting to a stop. Can be used for frequent starting and stopping
- Diagnostic LEDs: Current Limit, Inhibit, Power, Run
- On-board Fuses: Drive includes an on-board fuse
|
Technical Data
- 1.37 Form Factor
- 2% Base Speed Regulation
- 60:1 Speed Range
|
Trim Pots
- Maximum Speed
- Minimum Speed
- Acceleration
- Deceleration
- Current Limit