LGC400-10 DC Motor FMCopy

LGC Series

The LGC series is our most widely used series for general purpose 90/180 VDC brushed DC motor applications. This compact, non-filtered SCR drive series offers many user friendly adjustments. With the use of the on-board trim pots you can quickly set maximum speed, acceleration rate, deceleration rate, current limit, speed regulation, and minimum speed of your motor. With abilities to accept 115 or 230 VAC single phase power, run permanent magnet or field-wound motors, the LGC series can easily satisfy most of your motor driving needs.

Potentiometer Kit 202-0031 is included with a purchase of the LGC400-10

Let's Talk About Your Project

Specification Ratings

Power Specifications

AC Line Input 115 / 230 VAC ± 10%, 50/60 Hz, Single Phase (1Ø)
Armature Voltage with 115 VAC (with 230 VAC) 90 VDC (180 VDC)
Continuous Armature Current (with Heat Sink) 5 amps (10 amps)
Horsepower Range at 90 VDC (with Heat Sink) 1/8 - 1/2 HP (1/8 - 1 HP)
Horsepower Range at 180 VDC (with Heat Sink) 1/4 - 1 HP (1/3 - 2 HP)
Field Voltage with 115 VAC (with 230 VAC) 50 / 100 VDC (100 / 200 VDC)
Maximum Field Current 1 amp

Logic Specifications

Analog Signal Control Range with 90 VDC output isolated 0 - 1.4 VDC
Analog Signal Control Range with 180 VDC output isolated 0 - 2.8 VDC
Built-in Isolation No
Input Impedance between S1 to S2 >100k ohms
Potentiometer 10k ohms

Technical Specifications

Control Technology SCR
Form Factor 1.37
Speed Range 60:1
Load Regulation <1% of base speed
Control Method Speed Control
Acceleration Time Range with 90 VDC output 0.5 - 11 seconds
Acceleration Time Range with 180 VDC output 0.5 - 22 seconds
Deceleration Time Range with 90 VDC output coast to stop - 13 seconds
Deceleration Time Range with 180 VDC output coast to stop - 25 seconds

Physical Specifications

Vibration 0-50 Hz (>50 Hz) 0.5G maximum (0.1G maximum)
Ambient Temperature Operating Range 32°-131°F (0°-55° C)
Weight 0.7 lbs (318g)

Features

  • ACE Footprint: Traditional ACE mounting pattern and footprint
  • Field Supply: Voltage output to energize the field winding of a shunt-wound motor
  • Stopping Modes: Inhibit (N.O.) for coasting to a stop. Can be used for frequent starting and stopping
  • Diagnostic LEDs: Current Limit indication
LGC400-10 DC Motor Control
$217.17

Contact the factory for volume pricing

Frequently Asked Questions

A heat sink is required when the continuous output current exceeds 5 amps. The 223-0159 Heat Sink Kit is available as an accessory and is recommended for applications running at or near full rated current.